PH2 - Projector Hinge
Installation: RS232 and Operation Details
SLQV
RS232
- Use an RJ25 connector in the socket marked
RS232 on the control box to operate using RS232
Details
Baud rate: 9600
Stop bit: 1
Parity: None
Databits: 8
Pin 1: RX
Pin 6 : TX
Pin 3 & 4: GROUND
Pin 2: TX
Pin 3: RX
Pin 5: GROUND
IMPORTANT
Ensure protocol is entered
exactly as written.
RJ25 9 PIN D
PIN 1: RX TO PIN 2: TX
PIN 6: TX TO PIN 3: RX
PIN 3: GROUND TO PIN 5: GROUND
PIN 4: GROUND TO PIN 5: GROUND
Protocol Action
fa_in Carriage Return (Enter ) Device IN
fa_out Carriage Return (Enter ) Device OUT
fa_stop Carriage Return (Enter ) Device STOP (At any position)