AC1
Gives an ouput of 240V(or 110V) to
control the Plasma Lift motor.
Outputs stay live for 60 seconds after
the OUT or IN functions are selected.
DC1
A low voltage connection for the
switches in the mechanism.
The four LEDs indicate the
state the mechanism is in.
CC1 Not Lit: Flap is OPEN
CC2 Not Lit: Flap is CLOSED
CC3 Not Lit: Beam is DOWN
CC4 Not Lit: Beam is UP
EMERGENCY STOP
This connection will stop all
functions of the mechanism
once broken / removed. Red
LED will also be on.
Contact Closure LEDs
To show the contact closure
operation is working correctly.
LEDs are on when connections
are shorted together.
D
C2
Gives an ouput to
control the Plasma
Hinge motor.
DC2
A low voltage connection for the
switches in the mechanism.
The LEDs indicate the
state the mechanism is in.
CC1 Not Lit: Hinge is IN
CC2 Flashes
: Hinge is OUT
CC1 & CC2 Lit: Home position
Operation Details
Sheet 16
of 17
ISSUE: 006
www.futureautomation.co.uk
FUTURE
AUTOMATION
PLH
Plasma Lift Hinge Mechanism
Instruction Sheet